NEW STEP BY STEP MAP FOR PERKINELMER AUTOSAMPLER

New Step by Step Map For perkinelmer autosampler

New Step by Step Map For perkinelmer autosampler

Blog Article

Mixing by aspiration—mixing of sample by aspiration as opposed to shaking ensures homogeneity of your sample and maintains cell viability

The CytKick Max Autosample encompasses a Enhance mode that allows more quickly sample processing, and passive cooling for some plates/racks. A CytKick Max Accessory Kit is involved which contains four accessory plates: two cooling plates and two tube adaptors, as well as a Max dongle essential. A pc is not really integrated Together with the autosampler since 1 is provided with the cytometer.

To forestall probe crashes, which can have to have expensive probe replacement, the CytKick Max Autosampler instantly performs a probe self-calibration to aid guarantee reliable positioning of your probe in just every nicely. The self-calibration verifies correct perform from the probe, minimizes variability in probe positioning as time passes to stop failures throughout plate runs, and allows make improvements to trustworthiness about the life of the method.

In contrast to other plate loaders that blend samples by shaking, which can not make certain homogeneity from the sample, the CytKick Max Autosampler mixes samples by aspiration and stirring, enabling uniform mixing whilst preserving sample viability and causing reliable knowledge with CVs under ten% over the plate. The CytKick Max Autosampler also has a gentle blend method for fragile cell traces.

The autosampler’s indicator lights and warning programs have already been designed to ensure that a consumer who has walked clear of the technique can certainly see the system standing all the time.

To take care of program adaptability, the guide sample probe is often accessible even though the loader is present, and switching amongst tubes and plates is detected perkin elmer autosampler via software package and will not involve further person intervention.

The CytKick Max Autosampler was created to lower program down time. Automatic sampling devices are sometimes stricken by clogging or probe crashes. The Intelligent Probe, by using a two hundred-micron diameter that's much larger than most probes available inside the marketplace, minimizes instances of clogging.

The intuitive application will allow fast Understanding and facts Examination. One example is, a warmth map view enables speedy screening and confirmation of samples even though the instrument is buying facts.

Quick changeover—no disassembly, no additional QC, no reboot needed for conversion among plates and tubes

The CytKick Max Autosampler has two choices for processing samples in the significant-throughput natural environment: superior-throughput manner and Raise method.

Self-calibration with the probe also lets the autosampler being quickly moved, so it could be shared amongst several instruments.

The instrument style and software program were developed with shopper simplicity-of-use in mind. The CytKick Max Autosampler has fluidic bottles with sensors that advise the consumer once the fluids have to get replaced.

Autocleaning of autosampler is completed through the instrument shutdown procedure therefore no supplemental consumer actions are demanded to keep up method.

Starting an experiment Along with the Attune NxT cytometric computer software is simple. Utilizing a plate layout watch, customers can create compensation wells, determine instrument options, and detect samples.

Report this page